8
FHPP standard data (I/O data)
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
135
Status byte 2 (SPOS)
The status of the positioning task “record selection mode” or “direct mode”, homing mode, jog mode
and the end of the teach procedure is reported back through the status byte 2 (SPOS).
Status byte 2 (SPOS)
Bit
DE
EN
Description
B0
HALT
Halt
Halt
= 1:
Halt is not active. Positioning task, homing or jog
ging can be carried out.
= 0:
Halt is active.
B1
ACK
Acknowledge
start
Ack
nowledge
Start
= 1:
Start executed (positioning task/homing)
= 0:
Ready for start (positioning task/homing)
B2
MC
Motion com
plete
M
otion
C
omplete
= 1:
–
Positioning task, homing or jogging is completed.
= 0:
Positioning task, homing or jogging is active.
Note:
MC is set for the first time after Power ON in the FHPP
status “EMCA switched on (S1)”.
B3
TEACH
Acknowledge
teach/
sampling
Acknowledge
Teach
/
Sampling
= 1:
Teaching performed. Position actual value has
been taken over into the main memory.
= 0:
Ready for teaching
B4
MOV
Axis is moving
Axis is
Mov
ing
= 1:
Speed of the axis . internal limit value
= 0:
Speed of the axis < internal limit value
B5
FOLERR
Following error
FOL
lowing
ERR
or
= 1:
Following error is present.
= 0:
Following error is not present.
B6
STILL
Standstill
monitoring
Stand
still
Con
trol
= 1:
Axis is in the tolerance window after MC.
= 0:
Axis is not in the tolerance window after MC.
B7
Ref
Drive refer
enced
Axis
Ref
erenced
= 1:
Reference point is present. Homing does not have
to be performed.
= 0:
Homing must be performed.
Tab. 8.15
Status byte 2
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......