F
Diagnostics and fault clearance
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
395
Diagnostic messages and fault clearance
29h
Target position behind negative software limit
Definable as:
F
/-/-
Diagnostic memory: optional
The start of a positioning task was suppressed because the target lies behind the negative software
limit position.
Check target data.
Check positioning area.
Check position set type (absolute/relative?).
–
Resettable: Error can be reset immediately.
Parameterisable error response(s):
B
, C, E, F
2Ah
Target position behind positive software limit
Definable as:
F
/-/-
Diagnostic memory: optional
The start of a positioning task was suppressed because the target lies behind the positive software
limit position.
Check target data.
Check positioning area.
Check position set type (absolute/relative?).
–
Resettable: Error can be reset immediately.
Parameterisable error response(s):
B
, C, E, F
2Bh
Firmware update, invalid firmware
Definable as:
F
/W/-
Diagnostic memory: optional
The firmware update process could not be performed. The firmware version is incompatible with the
hardware used.
Determine the version of the hardware. You can ascertain the compatible firmware designs and
download the appropriate firmware from the Festo website.
–
If parameterised as an error: Error can be reset immediately.
Definable error response(s):
A
–
For parameterisation as a warning: The warning disappears if a new FW download process is star
ted.
2Ch
FHPP incorrect record number
Definable as:
F
/W/I
Diagnostic memory: optional
An attempt has been made to start a record with an invalid record number.
Select a new record with a valid record number.
–
If parameterised as an error: Error can be reset immediately.
Definable error response(s):
F
, G
–
If parameterised as a warning: The warning disappears when a record with a valid record number
is started.
2Dh
I²t warning motor
Definable as: -/
W
/I
Diagnostic memory: optional
The I²t warning limit for the motor is reached.
Parameterise message as a warning or suppress completely as information.
–
For parameterisation as a warning: The warning disappears if the I²t integral is below 80%.
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......