B FHPP+
Festo – EMCA-EC-C-HP-EN – 2017-11e – English
239
B
FHPP+
B.1
FHPP+ data
B.1.1
Function
The FHPP+ data are an expansion of the FHPP standard data and are used for cyclical transmission of
mappable parameters (PNU). In the FHPP message, up to 16 or 24 bytes of “control and status data”,
depending on the configuration, can be used for the FHPP+ data. In the FHPP+ control data, additional
setpoint values can be specified that are not implemented in the control bytes of the FHPP standard
data. Additional actual values can be output in the FHPP+ status data, such as the current DC link
voltage or the temperature of the output stage.
The FHPP+ data can only be configured through the FHPP+ Editor of the FCT plug-in EMCA.
Only mappable FHPP parameters (PNU) can be used as parameters for this purpose. Non-
mappable FHPP parameters (PNU) are not transmitted.
B.1.2
Structure of the FHPP message
In the FHPP message, the following bytes can be used for the FHPP+ data.
16 bytes FHPP+ data
FHPP message with parameter channel (FPC) (byte 1 ... 32)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
FHPP standard data
(8 bytes)
FPC parameter channel
(8 bytes)
FHPP+ data
(Max. 16 bytes)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16
Tab. B.1
16 bytes FHPP+ data
24 bytes FHPP+ data
FHPP message without parameter channel (FPC) (byte 1 ... 32)
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
FHPP standard data
(8 bytes)
FHPP+ data
(Max. 24 bytes)
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
Tab. B.2
24 bytes FHPP+ data
Summary of Contents for EMCA-EC-67 CO Series
Page 33: ...2 CANopen Festo EMCA EC C HP EN 2017 11e English 33 ...
Page 73: ...3 EtherCAT with FHPP Festo EMCA EC C HP EN 2017 11e English 73 ...
Page 87: ...4 EtherNet IP with FHPP Festo EMCA EC C HP EN 2017 11e English 87 ...
Page 113: ...6 PROFINET IO with FHPP Festo EMCA EC C HP EN 2017 11e English 113 ...
Page 116: ...7 FHPP 116 Festo EMCA EC C HP EN 2017 11e English ...
Page 140: ...8 FHPP standard data I O data 140 Festo EMCA EC C HP EN 2017 11e English ...
Page 148: ...9 Measuring reference system 148 Festo EMCA EC C HP EN 2017 11e English ...
Page 210: ...10 Control via FHPP 210 Festo EMCA EC C HP EN 2017 11e English ...
Page 223: ...11 Monitoring of the drive behaviour Festo EMCA EC C HP EN 2017 11e English 223 ...
Page 367: ...D CANopen communication Festo EMCA EC C HP EN 2017 11e English 367 ...
Page 402: ...F Diagnostics and fault clearance 402 Festo EMCA EC C HP EN 2017 11e English ...
Page 413: ...EMCA EC 67 CO DIO EC EP PN Festo EMCA EC C HP EN 2017 11e English 413 ...
Page 414: ...EMCA EC 67 CO DIO EC EP PN 414 Festo EMCA EC C HP EN 2017 11e English ...
Page 415: ......