6
Positioning mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
83
Timing diagram: interrupt record sequence via halt positioning sequence signal
Start record sequence
(DIN8)[X1.23]
Stop
(DIN13)[X1.15]
Halt record sequence
(DIN3)[X1.8]
Motion complete
(DOUT1)[X1.12]
Controller ready for operation
(DOUT0)[X1.24]
Confirm start
(DOUT2)[X1.25]
Common error
(DOUT3)[X1.13]
Speed
(Positioning record 1/2/3)
t2
1
Record selection bit 0…2
(Positioning record 1…7)
(DIN…)[X1.…]
t3
t1
t2
t3
t6
2
3
t5
t5
t4
t4
2
3
t1
≥
2.5 ms
t2
≤
5 ms
t3
L
16 ms
t4
= … ms (FCT: dependent on the deceleration
ramp)
t5
= … ms (FCT: dependent on the acceleration
ramp)
t6
= … ms (FCT: dependent on the parameters
“Message window” and “Damping time” in
the message “Target reached”)
Fig. 6.14 Timing diagram: interrupt record sequence via halt positioning sequence signal