![Festo CMMS-AS-G2 Series Description Download Page 156](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130156.webp)
A
Diagnostic messages
156
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
Error group 64
DeviceNet error
No.
Reaction
Message
Code
64-2
7582h
DeviceNet communication error
PS off
Cause
–
Receive buffer overflow.
–
Too many messages received within a short period.
Measure
•
Reduce the scan rate.
64-3
7582h
DeviceNet communication error
PS off
Cause
–
Send buffer overflow.
–
Insufficient free space on the CAN bus to transmit messages.
Measure
•
Increase the baud rate.
•
Reduce the number of nodes.
•
Reduce the scan rate.
64-4
7582h
DeviceNet communication error
PS off
Cause
IO-message could not be sent
Measure
•
Check that the network is connected correctly and does not
malfunction.
64-5
7582h
DeviceNet communication error
PS off
Cause
Bus off.
Measure
•
Check that the network is connected correctly and does not
malfunction.
64-6
7582h
DeviceNet communication error
PS off
Cause
Overflow in the CAN controller.
Measure
•
Increase the baud rate.
•
Reduce the number of nodes.
•
Reduce the scan rate.
Error group 65
DeviceNet error
No.
Code
Message
Reaction
65-0
7584h
DeviceNet general error
Configurable
Cause
–
Communication is activated, even though no interface is
plugged in.
–
The DeviceNet interface is attempting to read an unknown
object.
–
Unknown DeviceNet error.
Measure
•
Check whether the DeviceNet interface is plugged in correctly.
•
Check that the network is connected correctly and does not
malfunction.
65-1
7582h
DeviceNet communication error
Configurable
Cause
I/O connection timeout.
No I/O message received within the expected time.
Measure
•
Please contact Technical Support.
Summary of Contents for CMMS-AS-G2 Series