![Festo CMMS-AS-G2 Series Description Download Page 159](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130159.webp)
A
Diagnostic messages
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
159
Diagnostic messages
Code
Reaction
Message
No.
7584h
64-1
DeviceNet general error
PS off
65-0
DeviceNet general error
Configurable
7680h
29-0
No SD available
Configurable
7681h
29-1
SD initialization error
Configurable
7682h
29-2
SD parameter set error
Configurable
8000h
45-0
Error, driver supply
PS off
45-1
Error, driver supply
PS off
45-2
Error, driver supply
PS off
05-2
Error, driver supply
PS off
8087h
45-3
DIN4 plausibility error
PS off
8130h
12-4
CAN: time-out nodeguarding
Configurable
8181h
12-0
CAN: general error
Configurable
12-1
CAN: error bus off
Configurable
12-2
CAN: error when transmitting
Configurable
12-3
CAN: error when receiving
Configurable
12-5
CAN: error in the IPO mode
Configurable
8600h
42-4
Message, homing required
Configurable
8611h
17-0
Following error monitoring
Configurable
8612h
40-0
Negative software limit switch reached
Configurable
40-1
Positive software limit switch reached
Configurable
40-2
Target position lies behind the negative software limit switch
Configurable
40-3
Target position lies behind the positive software limit switch
Configurable
43-0
Negative limit switch error
Configurable
43-1
Positive limit switch error
Configurable
43-9
Fault in limit switch
Configurable
8681h
42-1
Positioning: error in pre-computation
Configurable
8A81h
11-1
Homing error
PS off
Summary of Contents for CMMS-AS-G2 Series