![Festo CMMS-AS-G2 Series Description Download Page 160](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130160.webp)
A
Diagnostic messages
160
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
A.4
PROFIBUS diagnostics
Diagnostic messages
Unit_Diag_Bit
No.
Message
Reaction
00
E429
Position data set
42-9
Error in position record
PS off
01
E703
Operating mode
70-3
Operating mode error
Configurable
02
E702
Arithmetic error
70-2
General arithmetic error
PS off
03
E421
Position
pre-computation
42-1
Positioning: error in
pre-computation
Configurable
04
E163
Unexpected state
16-3
Unexpected status /
programming error
PS off
05
E010
Stack overflow
01-0
Stack overflow
PS off
06
E261
Checksum error
26-1
Checksum error
PS off
07
E162
Initialization
16-2
Initialization fault
PS off
08
E290
No SD available
29-0
No SD available
Configurable
09
E291
SD initialization
29-1
SD initialization error
Configurable
10
E292
SD parameter set
29-2
SD parameter set error
Configurable
13
E222
PROFIBUS
communication
22-2
PROFIBUS communication error
Configurable
14
-
unknown
12-x
Unknown error (CAN)
Configurable
15
E790
RS232 communication
error
79-0
RS232 communication error
Configurable
18
E418
Record seq. unknown
cmd
41-9
Error, jump destination path
program
Configurable
19
E419
Record seq. invalid
dest.
41-8
Error, jump destination path
program
Configurable
20
-
unknown
64-x
Unknown error (DeviceNet)
PS off
65-x
Unknown error (DeviceNet)
Configurable
23
E220
PROFIBUS assembly
22-0
Error in PROFIBUS initialization
Configurable
26
E351
Time out: Quick stop
35-1
Time out for quick stop
PS off
27
E111
Error during homing
11-1
Homing error
PS off
31
E149
Motor identification
14-9
Error, motor identification
PS off
33
E190
I2t at 80 %
19-0
I²T at 80 %
Configurable
35
E181
Outp. stage temp. 5 <
max.
18-1
Output stage temperature
5 °C below maximum
Configurable
36
E170
Following error
17-0
Following error monitoring
Configurable
37
E424
Enforce homing run
42-4
Message, homing required
Configurable
38
E43x
limit switches
43-0
Negative limit switch error
Configurable
43-1
Positive limit switch error
Configurable
43-9
Fault in limit switch
Configurable
Summary of Contents for CMMS-AS-G2 Series