7
Speed mode and force/torque mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
121
7.2.2
Function: force/torque mode
In the force/torque mode, the motor controller can be controlled via the active fieldbus (CANopen/
PROFIBUS DP/DeviceNet/RS485) or analogue input. Through the direct application (fieldbus) or the
analogue setpoint value (analogue input), the current control (torque) receives the current setpoint
value.
No homing is required with force/torque mode.
7.2.3
Activate force/torque mode via fieldbus/analogue input
X4
CMMS-AS-...-G2
CANopen
PROFIBUS DP
RS485
Analogue input
Fieldbuses
Control section
X1
EXT
X5
DeviceNet
Input
Direct application
Analogue setpoint value
Current regulation
Fig. 7.6
Overview: activate force/torque mode via fieldbus or analogue input