Positioning mode
82
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
6.5.4
Timing diagram: start/interrupt/cancel record sequence
Timing diagram: start record sequence via start positioning sequence signal
Start record sequence
(DIN8)[X1.23]
Stop
(DIN13)[X1.15]
Halt record sequence
(DIN3)[X1.8]
Motion complete
(DOUT1)[X1.12]
Controller ready for operation
(DOUT0)[X1.24]
Confirm start
(DOUT2)[X1.25]
Common error
(DOUT3)[X1.13]
Speed
(Positioning record 1/2/3)
t3
1
Record selection bit 0…2
(Positioning record 1…7)
(DIN…)[X1.…]
t4
t2
t3
t4
t5
2
3
t1
t1
≤
2.5 ms
t2
≥
2.5 ms
t3
≤
5 ms
t4
L
16 ms
t5
= … ms (FCT: dependent on the parameters
“Message window” and “Damping time” in
the message “Target reached”)
Fig. 6.13 Timing diagram: start record sequence via start positioning sequence signal