![Festo CMMS-AS-G2 Series Description Download Page 69](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130069.webp)
6
Positioning mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
69
6.2.4
Parameterise positioning record profiles
The following settings can be parametrised in the Festo Configuration Tool (FCT):
Parameters
Description
Position record profiles:
Speed
Setpoint value for positioning speed.
Acceleration
Setpoint value for acceleration.
Deceleration
Setpoint value for deceleration.
Smoothing
Value for duration of filtering from acceleration and deceleration ramps
page 71.
Time
Setpoint value for how long the positioning record in the record sequence
should be executed until continuation is executed. This parameter becomes
active with the positioning record parameter “Command: TIM”.
Start delay
Setpoint value for the waiting time after the start signal until the current
setpoint value is to be executed/the drive should be moved.
Final speed
Setpoint value for travel with final speed to run through the target position.
After that, travel continues with final speed.
Start condition
Start conditions for the subsequent positioning record in individual or
record-chaining operation.
If the motor controller receives a new start signal (DIN8) during the active
positioning record, the reaction of the controller-internal positioning control can
be controlled via the parametrised start condition as follows:
–
Ignore: The start signal (DIN8) for the new positioning record is not evalu-
ated.
–
Wait: The current positioning record is executed completely and after that
the new positioning record is started.
–
Interrupt: The current positioning record is interrupted and the new posi-
tioning record is started immediately.
Tab. 6.4
Overview: positioning record profile parameter
Summary of Contents for CMMS-AS-G2 Series
Page 173: ......