6
Positioning mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
75
6.3.4
Parameterise direct mode
The following settings can be parametrised in the Festo Configuration Tool (FCT):
Parameters
Description
Positioning mode:
Base value of speed
Base value for the “Speed” setpoint value
The “Speed” setpoint value is calculated by multiplying “Base value”
and “Speed factor (%-value)”. The speed factor is transmitted
cyclically via the fieldbus.
Acceleration
Setpoint value for acceleration to speed.
Deceleration
Setpoint value for deceleration to rest.
Smoothing
Value for duration of filtering from acceleration and deceleration ramp
page 71.
Tab. 6.7
Parameterise direct mode