Homing to zero pulse signal (N/#N)
Code
Description
hex
dec
22h
34
Zero pulse in positive direction
1)
1. Search for zero pulse in the positive direction:
Travel with “Crawl” speed in a positive
direction until the first zero pulse has been
detected. This position is taken as the homing
point.
2. If an axis zero point is parametrised and the
FCT option “Travel to axis zero point after
homing” is activated:
travel with “Run” speed to the axis zero point.
Zero pulse
21h
33
Zero pulse in negative direction
1)
1. Search for zero pulse in the negative direction:
Travel with “Crawl” speed in a negative
direction until the first zero pulse has been
detected. This position is taken as the homing
point.
2. If an axis zero point is parametrised and the
FCT option “Travel to axis zero point after
homing” is activated:
travel with “Run” speed to the axis zero point.
Zero pulse
1)
Motors have shaft encoder with zero pulse as standard.
Tab. 6.14
Overview: homing to zero pulse signal (N/#N)