![Festo CMMS-AS-G2 Series Description Download Page 31](http://html1.mh-extra.com/html/festo/cmms-as-g2-series/cmms-as-g2-series_description_2283130031.webp)
3
Control interfaces
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
31
Timing diagram: motion complete signal
The timing diagram “Motion complete signal” is depicted here as an example for all messages with
message window and damping time. All other messages behave identically regarding the timing pro-
cess.
Speed
Motion complete
(DOUT1)[X1.12]
“Damping time” start
Positioning path
t1
Positioning record parameter
“Position”
s+
s–
t1
“Damping time” termination
s+/– Linear axis = … mm
Rotational axis = … R
(FCT: dependent on the parameter “Message
window” in the message “Target reached”)
t1
= … ms (FCT: dependent on the parameter
“Damping time” in the message “Target
reached”)
Fig. 3.2
Timing diagram: motion complete signal