6
Positioning mode
Festo – GDCP-CMMS-AS-G2-FW-EN – 1310NH – English
65
6.2.2
Actuate record selection/positioning record via fieldbus or digital inputs
X4
CMMS-AS-...-G2
CANopen
PROFIBUS DP
Digital inputs
Fieldbus
Control section
X1
EXT
DeviceNet
Inputs
Record
selection:
0…63
Positioning
record:
0…63
Position record
profile:
0…7
Bit 0…5
Position
control
Controller-in-
ternal position-
ing control
Fig. 6.2
Overview: Actuate record selection/positioning record via fieldbus or digital inputs
Actuate positioning records
The following positioning records can be actuated, dependent on the control interface and operating
mode:
Control interface
Operating mode
Single position
operation
Record linking
operation
Homing mode
Teach mode
CANopen
Positioning
record 1…63
Positioning
record 1…63
Positioning
record 0
Positioning
record 1…63
PROFIBUS DP
DeviceNet
Digital inputs (DIN)
Positioning
record 1…63
(Mode 0)
Positioning
record 1…7
(Mode 2)
Positioning
record 0
(Mode 0)
Positioning
record 1…63
(Mode 1)
Tab. 6.1
Overview: Actuate positioning records