2 Global Overlap
2-11
2
Display Limitations
• When the global overlap display has been hidden by the internal command (switch or macro
command) after it was brought up by the external command, bit 3 of the external command must
be set (0
→
1) to display the global overlap display again. It is recommended that you use the
external command to hide the overlap display once it has been shown by the external command.
• Note that the overlap display with “superimpose” is placed over the global overlap display.
• When the global overlap display with “superimpose” is shown, the transparent color and the blend
value become the same as those set for the screen on which the global overlap display first
appeared.
• The global overlap display is not shown while the login screen registered on the [Security Setting]
dialog is displayed.
After the screen display is switched to another, the global overlap display will be shown.
• The global overlap display will be shown again after any of the following functions is executed.
• The macro command CHG_LANG has been executed to change the language.
• The item placed on the global overlap display has been shown/hidden.
• The offset memory value of the item placed on the global overlap display has been changed.
• The overlap display of the same overlap library number has been displayed while the global
overlap display is displayed.
• The data block area cannot be used on the global overlap display. If used in this way, the contents
in the data block area will not be displayed on MONITOUCH.
“Warning” is displayed on the [Error Check] window in the following cases:
• In the case where [Designate: Internal] is selected and the macro command “SET_MOVLP” is
used or [Designate: External] is selected:
Do not specify the overlap library number of the data block area for the global overlap display.
• In the case of the [Function: Multi-Overlap Display] switch with [Designate: Internal] selected:
Change the overlap library number, or delete the data block area from the specified overlap
library.
• When the global overlap display is used, “3” cannot be specified for [Order INC] in the [Detail] tab
window in the [Data Block Area] dialog. Specify a value from 0 to 2 for [Order INC].
• The global overlap display cannot be set for component parts. It cannot be called up from
component parts.
Summary of Contents for MONITOUCH V8 SERIES
Page 1: ...Reference Additional Functions V8series...
Page 57: ...2 Global Overlap 2 12 Please use this page freely...
Page 101: ...7 2 Panel Meter Extended 7 18 Please use this page freely...
Page 123: ...9 2 Acknowledge Function 9 18 Please use this page freely...
Page 127: ...10 RGB Display touch switch emulation 10 4 Please use this page freely...
Page 187: ...14 3 Addition of Titles to a CSV File Sampling Data 14 20 Please use this page freely...
Page 199: ...15 Item Show Hide Function 15 12 Please use this page freely...
Page 213: ...16 FTP Server 16 14 ls command This command is used to display the names of files and folders...
Page 221: ...16 FTP Server 16 22 Please use this page freely...
Page 233: ...17 2 Two Ethernet Ports 17 12 Please use this page freely...
Page 241: ...18 Network Camera 18 8 5 The Live view window is displayed...
Page 261: ...18 Network Camera 18 28 Please use this page freely...
Page 327: ...20 MES Interface Function 20 38 6 The table is created...
Page 369: ...22 Security Function 22 12 Please use this page freely...
Page 429: ...24 Tag 24 24 Please use this page freely...
Page 491: ...26 6 USB FDD Floppy Disk Drive 26 14 Please use this page freely...
Page 503: ...27 Ladder Transfer via USB or Ethernet 27 12 Please use this page freely...