NOTICE!
Electric components can be dam-
aged by water entering into the
system!
– Protect electrical equipment such
as generator, regulator and
starter against the direct water
jet.
1.
Park the machine in secured condition
Chapter 6.7 „Park the machine in
secured condition.“ on page 115
.
2.
Allow the engine to cool down.
The air conditioning condenser is
located in front of the radiator.
3.
CAUTION!
Danger of eye injuries caused
by particles flying around!
– Wear your personal protec-
tive equipment (safety
gloves, protective working
clothes, goggles).
Clean the condenser fins with compressed
air or cold water.
Fig. 134
Maintenance – Every 500 operating hours
BW 213 D-5
176
Summary of Contents for BOMAG BW 213 D-5
Page 2: ...2...
Page 9: ...1 Introduction Introduction BW 213 D 5 9...
Page 14: ...Introduction Machine type plate and engine type plate BW 213 D 5 14...
Page 15: ...2 Technical data Technical data BW 213 D 5 15...
Page 20: ...Technical data Noise and vibration data BW 213 D 5 20...
Page 21: ...3 Concerning your safety Concerning your safety BW 213 D 5 21...
Page 63: ...4 Display and control elements Display and control elements BW 213 D 5 63...
Page 82: ...Display and control elements Outside of machine BW 213 D 5 82...
Page 83: ...5 Tests before taking into operation Tests before taking into operation BW 213 D 5 83...
Page 95: ...6 Operation Operation BW 213 D 5 95...
Page 124: ...Operation Emergency procedures BW 213 D 5 124...
Page 125: ...7 Loading transporting the machine Loading transporting the machine BW 213 D 5 125...
Page 133: ...8 Maintenance Maintenance BW 213 D 5 133...
Page 207: ...9 Trouble shooting Trouble shooting BW 213 D 5 207...
Page 217: ...10 Waste disposal Waste disposal BW 213 D 5 217...
Page 219: ...11 List of special tools List of special tools BW 213 D 5 219...
Page 220: ...Belt tension tester BOMAG No 079 947 09 Fig List of special tools BW 213 D 5 220...
Page 221: ......
Page 222: ......