5
Operational States
This page describes the different states of the blue LED flashlight (water indicator) There are
5 different light patterns of the water indicator:
Type
Meaning
Ready blinking
-
System ready, waiting for trigger condition (Water Monitoring
inactive)
Permanently on
-
Actually refuelling, monitoring active (AFGUARDs armed, if
“Delay Begin of Monitoring” and “Minmum Fuel for Monitoring”
are unset)
Slow flashing
(0.33Hz)
-
Water warning
Fast flashing
(2Hz)
-
Water Alarm (multiple Warnings, Alarm, Slug)
-
Caused by an AFGUARD or SLUGGUARD
Permanently off
-
Overflow Alarm,
-
Over DP Alarm,
-
Sensor Error,
-
Sensor cable break,
-
CCS unpowered
-
Override active
-
No USB drive plugged
-
invalid date and time / battery empty
Caution: When you begin refuelling, by pressing the deadman, please check, that the
blue indicator lamp turns on permanently within a few seconds. This is
very important
.
When the lamp is not lighting permanently, this means, that the water monitoring is
inactive.
The measured water values by the AFGUARD®(s) would be ignored and no
Alarms / Warnings were generated!