3.2.6.6 Software Override
In some cases, it can be helpful to deactivate the alarm functionality of the System. The CCS
supports an Override feature. To open the override mode, click on Override
You are asked for a PIN, Please enter the
Admin
PIN then the Override dialog will open.
With the button in the Override Time section, you can set up a time up to 60 min.
For this time, both relays REL_1 and REL_2 will stay in On-
position, they won’t get released
when an alarm / water slug / warning / error appears. To indicate the unreadiness of the
system, the blue lamp stays off.
The time begins with a click on Start.
The screen shows “Override active” and a countdown. Another Reset Button appears. By a
click on
Reset
the override mode will end immediately. The standard behaviour of the
system, the relays and the lamp come back.
A click on
Reset
has the same behaviour
than a hardware reset applied by a key switch.
You can also use the hardware reset to
end the override. Additionally, all alarms will be deleted.
It is very important to check if the blue indicator lamp gets back to the ready blink pattern.
By a click on
Start
the countdown starts again by the set time.
By repowering the system during the override period, the system starts again without
override.
3.2.6.7 Hardware Override
There is also the possibility to activate Override by a Digital Input. The input DI3 activates the
Override as well and holds it as long as DI3 is in High-State (24V). For Hardware Override
you do
n’t need to open the web visualisation to set an Override time.