3.2.6.2 Reset Alarm
3.2.6.2.1 Reset Alarm by Software
In any case of activated alarm
– additional touch button appears to reset alarm manually by a
touch on screen. Alarm could either be deactivated using external reset button. Please
consider that a SLUGGUARD alarm could not be reset through hardware reset switch or
reset button in the visualisation. A SLUGGUARD alarm resets automatically when water gets
drained at the SLUGGUARD mounting position.
By a press on the Reset Alarm button in the visualisation, a PIN Dialog appears.
You are asked to enter a PIN. For a reset you can insert the User PIN or the Admin PIN as
well. When the PIN is correct, there will be a dialog telling you to fix any . The dialog looks
like:
Water Alarm (above 30ppm
for 10 sec) in the outlet