4.
36
(MT13 - En 2015)
DV2420
DV2420
IN
COM
OUT
NC
NA
C
2281
LM
LM
LM
LM
LI LI
LO LO
PE
LI
LI
2281.
The actuator, designed for the DUO system,
allows to activate auxiliary services, such as addi-
tional door locks, staircase-lights, and rings without
adding wires on the riser line. It is provided with one
relay and one IN/OUT configurable port; the port
configured as output (OUT) activates a relay to
manage a second auxiliary service; when config-
ured as input (IN) it acquires information about the
status of the device connected to it, typically a
contact (switch, automatic stop device, etc.) that
sends open/close information.
By programming the device, the acquired information
can be sent on line and made available for other
devices in the system.
Multiple actuators can be connected in the same
installation by suitably programming the addresses
of the relay and the IN/OUT port of each actuator;
moreover, the activation time and operating modes
can be set for the relay and the port that was
configured previously as output.
The operating modes are:
- monostable (upon reception of the command, the
relay and/or port is activated for the programmed
time and then is deactivated)
- bistable (upon reception of the command the relay
and/or port changes its status from activated to
deactivated or vice versa until the next command,
which changes the status of the relay and/or port
again).
Technical data
Power supply directly from line or external:
13VAC ± 10%
Operating current:
0.1A
Load relay contacts: 12Vac/12÷24Vdc - 1A
Housing:
DIN 4 modules A
Operating temperature:
0° ÷ +50°C
Maximum permitted humidity:
90% RH
Fits on DIN bar or with 2 expansion plugs
Terminals
/
External power supply input
LM/LM Line inputs
IN
IN/OUT port input
COM
IN/OUT port common
OUT
IN/OUT port output
C
Relay contact common
NA
Relay normally open contact
NC
Relay normally closed contact
ACTUATOR MODULE
SERVICE MODULES
3
"
2
/
1
89
2
"
16
/
9
2
"
4
/
3
70
65
c) Connecting the actuator to an additional distributor DV2420
To connect the actuator in the proximity of the external door station or along the line of an
external door station, a DV2420 must be added as shown in the following examples.
- Connection in installation WITHOUT exchanger
(actuator power supply directly from line)
line to external door stations or exchangers
line to video distributors
line to riser
line to external door
stations
DV2420
LM
LM
LM
LM
IN
COM
OUT
NC
NA
C
2281
2221ML
2221S
LP
LP
127/230Vac
PI
LO LO
PE
LI LI
INSTALLATION
DM2444
LM
LM
LM
LM
IN
COM
OUT
NC
NA
C
2281
2221ML
2221S
LP
LP
LO1
LO2
LO1
LO2
LI1
LI2
LI1
LI2
PE 1
PE 2
Riser "a" Riser "b"
127/230Vac
b) Connecting the actuator to the distributor of risers DM2444
lines to external door stations
1
2 3
J1 = 2-3
1
2 3
J1 = 2-3
1
2 3
J1 = 2-3
a) Connecting the actuator to the distributor DV2420 of the installation