5.
23
(MT13 - En 2015)
5
PA
SE
2220S
FP
FP
C
S1
S2
2221ML
2221S
127V/230VAC
B
F
J1
LP
LP
LI
LM
LM
LM
LM
LM
LI
LM
LM
LM
LM
LM
A1
A1
A1
A1
GN
GN
GN
GN
LP
LP
A
E
E
DV2421...
LO LO
VC1b
VC2b
VC1a
VC2a
PE
127V/
230VAC
J*
J*
J*
J*
4
4
4
4
3
3
3
3
2
2
2
2
1
1
1
1
PA
SE
2220S
FP
FP
C
S1
S2
2221ML
2221S
127V/230VAC
B
F
J1
LP
LP
LI
LM
LM
LM
LI
LM
LM
LM
A1
A1
GN
GN
LP
LP
A
E
E
DV2421...
LO LO
VCb
VCa
PE
127V/
230VAC
Si 51VM/166
TWO-WAY VIDEOINTERCOM SYSTEM
Si 51VM/167
TWO-WAY VIDEOINTERCOM SYSTEM EACH WITH 2 PARALLEL VIDEOINTERCOMS
Q.ty Article
Description
2-4 ZH1262
Zhero videointercom
ML2083
myLogicOne videoin back box
WB3252
Exhito videoin wall bracket
WB3262
Exhito videoin wall bracket
9083
Echos videoin back box
1
DV2421..
Floor video distributor
1
2220S
Transformer
1
2221S-2221ML
Line power supply
2
FP **
Floor push-button (optional)
1
PA **
Door release button (optional)
1
SE **
Electric door lock (12Vac-1A)
AGORA' series door station
1
VD2121CAG-VD2121CAGL Videointercom door station
1
AG21-AGL21
Additional button for two-way system
PROFILO series door station
1
PL72
Back box with module frames
1
PL82
Hood cover
1
PL92 *
Rain shelter with module frames
1
VD2120CPL
Camera modules with integrated door speaker
1
CD2131PL
Digital encoder module with 1 button
MATRIX series door station
1
MA72
Back box with module frames
1
MA62
Front frame
1
MA92 *
Rain shelter with module frames
1
VD2120MA
Camera modules with integrated door speaker
1
CD2132MA
Digital encoder module with 2 buttons
* Rain shelters are used in replacement of back boxes and hood covers.
** Articles not supplied by ACI Farfisa.
See table 5.3 of the distance on page 5.6.
J... The jumper number depends on the internal station
model used. See table 5.4 on page 5.8.
Attention!
- Place the VC1 video intercom line termination jumper
J* between 3 and 4 (open line). Leave VC2 J* between
1 and 2 (closed with 100
Ω
).
- In both diagrams, remove jumper J1 from the line
power supply.
Notes
- The user code of external door stations and
videointercoms is 100 by default; for this reason, the
second videointercom must be programmed with the
next code 101 (see the programming of videointercoms
to chapter 2).
- Choose the video distributor according to the model of
videointercom preferred; see table 5.6 on page 5.8.
Programming to be performed
VC1b and VC2b - to change user address from 100 to
101
VC1 - sending floor call to videointercom VC2
VC2 - to change internal address from 000 to 001
V
I
D
E
O
I
N
T
E
R
C
O
M
S
Door station
Videointercom "a"
Videointercom "b"
Attention!!
Remove jumper J1
INSTALLATION DIAGRAMS
Videointercom "a"
Videointercom "b"
Door station
Attention!!
R e m o v e
jumper J1