![Farfisa EH9262CW series Technical Manual Download Page 37](http://html1.mh-extra.com/html/farfisa/eh9262cw-series/eh9262cw-series_technical-manual_3567673037.webp)
2.
27
(MT13 - En 2015)
2
Table 2.4 - Table of system programming codes
Programming
Function description
Default
Value entered with buttons
code
value
= 0
1 = 1
bit 0
send floor call to other internal stations in parallel (1)
NO
NO
YES
bit 1
button
deactivates all ring tones (2)
NO
NO
YES
bit 2
button
deactivates all ring tones and button tones (2)
NO
NO
YES
bit 3
button
does not deactivate ring tones and button tones (2)
NO
NO
YES
bit 4
reserved
NO
NO
-
bit 5
the GC-GE terminals are activated upon call from external door station (3)
NO
NO
YES
bit 6
the GC-GE terminals are activated upon intercom call (3)
NO
NO
YES
bit 7
Led indication of door-open
NO
NO
YES
(1) From the internal station connected to the floor call button FP and with programming value 1 for bit 0 the floor call is also sent to the other systems
in parallel.
(2) If bits 1, 2 and 3 are programmed with value 0 (NO), press the button
, without a conversation in progress, to deactivate the external and
intercom ring tones.
(3) If bits 5 and 6 are programmed with value 0 (NO), the GC and GE terminals are activate at the call and during the conversation.
More programming operations for specific functions
How to program secondary addresses
(additional programming operation that does
not depend on the programming operations
of user and internal station addresses)
The following programming operation allows
you to save 4 additional user addresses on the
same videointercom (i.e.: exchanger function,
videointercom installed in common area with
multiple users, etc.)
To make the programming it is necessary:
enter the programming mode following
the instructions described in “Enter the
programming mode”;
keep pressed the button “
” (right side) for
more than 4 seconds; red LED starts flashing;
enter the 3 digit of the 1st user address
(codes from 1 to 200) following the procedure
reported on the paragraph “Entering codes
or addresses”;
press the button
to confirm the present
address and move to the 2nd user address;
an acknowledge tone will be heard;
enter the 3 digit of the 2nd user address
and confirm by pressing button
;
proceed entering the 3rd and 4th address
consumer (if necessary) or to press twice the
button “
” to pass to the insertion of the
common inside address;
enter the 3 digit that compose the inside
INTERNAL STATIONS
address common to the 4 new user
addresses (codes from 000 to 007) following
the procedure of the paragraph “Entering
codes or addresses”.
Note: the internal address has to be unique
and different from you address him inside
eventually programmed on other videointer-
coms and/or intercoms that has the same
user address;
to press “
” to confirm and to return of
choice of programming; an acknowledge
tone will be heard and the red LED lights-ON
continuously;
proceed with another programming or exit
programming mode by pressing button
or
.
Note: If you want to make intercom calls, you
must program the call buttons with the codes of
the users you want to call.
Examples
Programming of three videointercoms (VC101,
VC102 and VC103), with one intercom with
reception of all three external calls (VC103).
a) programming with direct switch-on of
videointercoms upon their own call.
Videointercom 103 will receive all calls, but
will switch on only upon its own call.
VC101. User address = 101; internal address
= 000
VC102. User address = 102; internal address
= 000
VC103. User address = 103; internal address
= 000; programming secondary addresses
=101
102
001
b) programming with direct switch-on of
videointercom 103 only upon any call. The
other two videointercoms will receive the
call, but will stay off. Press the button
to
switch them on. In this case the intercom
service is not possible.
VC101. User address = 101; internal address
= 001
VC102. User address = 102; internal address
= 001
VC103. User address = 103; internal address
= 000; programming secondary addresses
=101
102
000
System programming
The following programming allows you to
personalise the operation mode of button “
”
used to deactivate the ring tones and the GC-
GE terminals and send the floor call to the
systems with the same user address (internal
stations in parallel). See table 4.
To make the programming it is necessary:
enter the programming mode following
the instructions described in “Enter the
programming mode”;
keep pressed the button “
” (right side) for
more than 4 seconds; red LED starts flashing;
press the key “
” and/or “1” eight times
according to the desired programming;
press “
” to confirm and return to pro-
gramming selection; you will hear the confir-
mation tone and the red LED will turn on and
stay on;
proceed with another programming or exit
programming mode by pressing button
or
.
Example
To activate the function illustrated in table 4 for
bits 0 and 2 and deactivate it for the other bits,
press the following buttons in a sequence:
1 1
.