3.
8
(MT13 - En 2015)
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
Lock actuation time (code 114). To change
the lock actuation time, you must:
enter the programming mode following the
instructions described in “Entering the pro-
gramming mode”;
enter code 114 and press Pn; you hear a
confirmation tone and the red LEDs start
flashing;
dial the number of seconds you want the door
lock to stay ON (3 digits from 000 to 120);
press Pn; you hear a confirmation tone and
the red LEDs go back ON without flashing;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
Operations with main or secondary door
keeper exchangers (code 116).
The following settings are necessary if in the
system are installed main and/or secondary
door keeper exchangers.
To make the programming you must:
enter the programming mode following the
instructions described in “Entering the pro-
gramming mode”;
enter code 116 and press Pn; you hear a
confirmation tone and the red LEDs start
flashing;
enter address 201 if the door station oper-
ates with 1 or more main door keeper ex-
changers or address 210 if the door station
operates with 1 or more secondary door keeper
exchangers;
press Pn; you hear a confirmation tone and
the red LEDs go back ON without flashing;
continue by entering the code of a new pro-
gramming or exit the programming mode by
moving the jumper J1 to position 1-2.
System programming (code 121)
This programming is used to activate or
deactivate the functions listed in table 3.2 on
page 3.9.
To make the programming you must:
enter the programming mode following the
instructions described in “Entering the
programming mode”;
enter code 121 and press Pn; you hear the
confirmation tone and the red LEDs flash
once every second to indicate that you are
programming mode 1;
a - press “P1” to activate/deactivate mode 1;
a low tone indicates deactivation, and a high
tone indicates activation;
b - press “Pn” to confirm and go to the next
programming; you hear a confirmation tone
and the red LEDs generate a series of
flashings to indicate the number of the next
mode; if you do not need to change one or
more operation modes, press “Pn” to go to
the next modes;
repeat actions a and b to programme all
modes 2, 3 and 4;
after programming and confirming mode 5
with “Pn”, press “Pn” three more times to exit
the system programming mode; you hear a
confirmation tone and the red LEDs go back
on without flashing.
DOOR STATIONS
Enter code 111 and press Pn; you hear a
confirmation tone and the red LEDs start
flashing.
Dial the code number you have chosen for
the external door station and press Pn to
confirm; you hear the confirmation tone
and the red LEDs go back ON without
flashing.
Continue by entering the code of a new
programming or exit the programming
mode by moving the jumper J1 to position
1-2.
Entering the First Button address (code
112)
The VD2121CAG (or AD2121CAG) board
has 2 buttons: PN and P1. PN is the first
button and P1 takes the next value (i.e.: Pn =
001, P1 = 002; Pn = 058, P1 = 059).
The first button (Pn) is coded by default with
address 100; if you want to change it, you
must:
enter the programming mode following
the instructions described in “Entering the
programming mode”;
enter code 112 and press Pn; you hear a
confirmation tone and the red LEDs start
flashing;
dial the address you want to assign to Pn.
Extensions must be coded with numbers
from 001 to 200;
press Pn; you hear a confirmation tone
and the red LEDs go back ON without
flashing;
continue by entering the code of a new
programming or exit the programming
mode by moving the jumper J1 to position
1-2.
Entering the address of the First Button
of the first additional push-button panel
(code 113).
To increase the number of calls, you must
integrate the VD2121CAG (or AD2121CAG)
external station with one or more additional
AG100TS push-button panels (max. 16).
Each additional push-button panel must be
coded with the 4 microswitches provided on
the board (see instructions attached to the
product). Moreover, an address must be
assigned to the first button of the first
additional push-button panel. The next buttons
of all the additional push-button panels will
automatically take progressive numbers. This
address must be higher than the address of
the P1 button of the VD2121CAG (or
AD2121CAG) external door station.
The first button (Pn) of the first additional
AG100TS push-button panel is coded by
default with address 102; if you want to
change it, you must:
enter the programming mode following
the instructions described in “Entering the
programming mode”;
enter code 113 and press Pn; you hear a
confirmation tone and the red LEDs start
flashing;
dial the address you want to assign to the
Pn button of the first additional push-but-
ton panel. Addresses must be numbers
from 001 and 200; remember that ad-
dresses 100 and 101 are assigned to the
2 VD2121CAG (or AD2121CAG) buttons
by default;
Entering codes or addresses
- Codes and/or addresses must have three
digits (hundreds, tens, units); codes and/or
addresses with tens and units or units only
must be completed by adding zeros. For
example, address 96 becomes 096 and
address 5 becomes 005.
- Enter one digit at a time by pressing the “P1”
button for a number of times “n”, where “n” is
the value of the digit you want to enter, followed
by a pause of about 2 seconds before you go
to the next digit (a tone on the loudspeaker will
tell you when to go to the next digit). The
maximum value you can enter is 255. For
example, to enter code 096 you must:
- press the “P1” button 10 times to enter digit
0 and wait for 2 seconds until you hear a tone
in the loudspeaker.
- press the “P1” button 9 times to enter digit 9
and wait for 2 seconds until you hear a tone on
the loudspeaker.
- press the “P1” button 6 times to enter digit 6
and wait for 2 seconds until you hear a tone on
the loudspeaker.
Note: - remember to confirm the codes you
have entered as explained in the
programming chapters.
Table 3.1. Programming codes
111 external door station address
112 first button address (Pn of VD2121CAG or
AD2121CAG door station)
113 address of first button of first Additional
Push-button Panel (Pn of the first
AG100TS)
114 door lock activation time
116 operation with door keeper exchangers
121 system programming (see table 3.2)
210 programming of call button with camera
deactivation during the call
211 button reset with camera deactivation
during the call
233 programming the buttons with special
functions
000 back to factory settings
Programming procedure
To make the programming it necessary to:
a) enter the programming mode following the
instructions described in “Entering the
programming mode”;
b) enter the three digits of the programming
code you want to change following the
instructions contained in “Entering codes or
address”; press PN to confirm: you hear the
confirmation tone and the red LEDs start
flashing.
c) make the operations described in the
specific programming chapter.
d) continue with another programming
operation or exit moving the jumper J1 from 2-
3 to 1-2.
Entering the External Door Station address
(code 111)
In this mode you can code the external door
station address with codes from 231 to 250.
Enter the programming mode following the
instructions described in “Entering the pro-
gramming mode”;