Description
DESCRIPTION
Ambie
nt a
nd
Op
erating
Co
nditio
ns
1.
Ref.2003
· 37 ·
QC-PDS
HARDWARE
1.6
Ambient and Operating Conditions
Terms
Regulation
Test reference
Mechanical specifications
Shipping
Vibration
Meets:
IEC 60721-3-2
Class 2M1, sinusoidal vibration
2 Hz
f
9 Hz, 3.5 mm amplitude
9 Hz
f
200 Hz, 1 g
200 Hz
f
500 Hz, 1.5 g
Jerk limit
Meets:
IEC 60721-3-2
IEC 61800-2
Class 2M1,
packed unit
Operation
Ambient sinusoidal
vibration tests
Meets:
CEI 60068-2-6,
Fc test
Sinusoidal vibration
10 Hz
f
57 Hz,
constant 0.075 mm amplitude
57 Hz
f
150 Hz,
1 g constant acceleration
Degrees of sealing
protection
(code IP)
Meets:
EN 60529
Open IP xx.
**
Always install inside
an electrical cabinet
Ambient conditions
Storage *
Ambient
temperature
Meets:
IEC 60721-3-1
IEC 61800-2
1K4,
From -25 ºC to +60 ºC
Shipping *
Damp heat test
(stationary state)
Meets:
IEC 60068-2-78
IEC 61800-5-1
Disconnected power supply
40ºC +/-2ºC and
93 % +2-3 % without condensation
Ambient
temperature
Meets:
IEC 60068-2-1
IEC 61800-2
Packed
unit
-40 °C to +70 ºC
Operation
Ambient test.
Cold
Meets:
CEI 61800-2
5 ºC in running
conditions
Ambient test.
Dry heat
Meets:
IEC 60068-2-2,
Bd test
Under nominal conditions of 45 °C.
Under running conditions between
5 ºC and 55 ºC with derating (see
derating characteristic).
Damp heat test
(stationary state)
Meets:
IEC 60068-2-78
IEC 61800-5-1
Disconnected power supply. 40 ºC
+/-2 ºC
93 % +2-3 % non-condensing
Installation altitude
over average
sea level without
derating
Meets:
IEC 61800-5-1
IEC 60664-1
Pollution degree 2
and altitude of
2000 amsl under
nominal conditions
*
The shipping and storage environment must be dry and dust free.
**
Open IP xx
, to be installed inside a cabinet or assembly that provides the required access
protection.
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......