Installation
INSTAL
LAT
ION
C
onne
cti
on
of the
con
trol
a
nd
communica
tions
signa
ls
8.
Ref.2003
· 299 ·
QC-PDS
HARDWARE
8.6.11 Connections for STO · Safe Torque Off · control signals
Refer to the examples in chapter
of chapter
All information regarding the X13, X13A and X13B connectors can be
found in chapter
MANDATORY.
ALWAYS make the connections using:
0.5 mm² cross-sectional conductors using a 10 mm sleeveless ferrule.
Maximum length of the stripped end, 8 mm.
or
0.34 mm² cross-sectional conductors using a 14.5 mm sleeved ferrule.
Length of ferrule, 10 mm. Maximum length of the stripped end, 12 mm.