Drives
138
3.
DRIVES
Single-dr
ives
· 118 ·
Ref.2003
· 118 ·
QC-PDS
HARDWARE
Installation
The connection is made by using two plates joining the (+/-) terminals of
the drive with the respective (+/-) terminals of the adjoining unit, which are
found behind the lid. See the figure.
F. H3/53
A17 terminals. Attaching the DC BUS to adjacent units.
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
2.5 mm²
MANDATORY.
The tightening torque to secure the plates to these
connection terminals must be between 2.3 and 2.8 N·m.