Installation
8.
INSTAL
LAT
ION
Locatio
n
302
Ref.2003
· 238 ·
QC-PDS
HARDWARE
8.1.3
Climatic considerations
The temperature inside the electrical cabinet containing the QC-PDS
system must not exceed 55 °C (131 °F).
The modules generate heat and when trying to decide whether the
electrical cabinet containing the QC-PDS system needs external cooling
or not, one must know the power dissipated by each one of its modules.
Refer to the table below to check the power dissipated by each element.
MANDATORY.
NEVER install the QC-PDS system next to a heat source.
T. H8/1
Dissipated power.
Non-regenerative
power supplies
power dissipated at maximum load
QC-PS-025
180 W
QC-PS-045
250 W
Regenerative
power supplies
power dissipated at maximum load
spindle S1 spindle S6-40%
crest/mean
QC-RPS-030-F
420 W
570/315 W
QC-RPS-160-
1860 W
2100/1200 W
Auxiliary modules
power dissipated at maximum load
QC-APS-15
63 W
QC-APS3-15
63 W
QC-CM-75
0 W
QC-BPM-100
5 W
ER+TH-18/
It depends on the activation frequency
of the Ballast protection circuit
ER+TH-18/
+FAN
MAIN FILTER 42A-A
15 W
MAIN FILTER 75A-A
20 W
MAIN FILTER 275
50 W
Single-drive
power dissipated at maximum load.
axis4|8 kHz spindle S1 spindle S6-40%
crest/mean
QC-DR-007-F
30/42 W
x
x
QC-DR-012-F
53/68 W
x
x
QC-DR-021-F
72/102 W
x
x
QC-DR-030-F
100/145 W
157 W
220 W
QC-DR-040-F
142/201 W
213 W
301/202 W
QC-DR-055-F
190/210 W
293 W
404/310 W
QC-DR-080-F
255/370 W
405 W
560/305 W
QC-DR-120-F
390/560 W
615 W
864/465 W
QC-DR-275-
x
1860 W
2100/1200 W
Dual-drive
power dissipated at maximum load
axis 4|8 kHz spindle S1 spindle S6-40%
QC-DR-07+07-FD2
39/55 W
x
x
QC-DR-12+12-FD2
69/88 W
x
x
QC-DR-21+21-FD2
93/132 W
x
x
QC-DR-30+30-FD2
96/140 W
x
x
Summary of Contents for QC-PDS
Page 1: ...DRIVE QC PDS Hardware manual Ref 2003...
Page 6: ...6 I 6 Ref 2003 6 QC PDS HARDWARE This page intentionally left blank...
Page 16: ...16 Ref 2003 16 Previous I QC PDS HARDWARE This page intentionally left blank...
Page 18: ...18 Ref 2003 18 Previous II QC PDS HARDWARE This page intentionally left blank...
Page 80: ...2 POWER SUPPLIES Power supplies 80 Ref 2003 QC PDS HARDWARE...
Page 138: ...3 DRIVES Drives 138 Ref 2003 QC PDS HARDWARE...
Page 174: ...4 AUXILIARY MODULES Auxiliary modules Ref 2003 174 QC PDS HARDWARE...
Page 302: ...8 INSTALLATION Installation Ref 2003 302 QC PDS HARDWARE...
Page 366: ...12 COMMERCIAL MODELS Commercial models Ref 2003 QC PDS HARDWARE 366...
Page 367: ...ANNEXES...
Page 368: ...ANNEX A1...
Page 383: ...ANNEX A2...
Page 398: ...ANNEX A3...
Page 418: ......
Page 419: ......