Work levels for sinusoidal 1 Vpp signal.
Characteristic.
Value.
Maximum frequency:
500 kHz.
A and B signals. Amplitude:
0.6 ÷ 1.2 Vpp
A and B signals. Centered:
|V1-V2| / 2 Vpp =< 6,5%
A and B signals. Ratio:
VApp / VBpp = 0.8 ÷ 1.25
A and B signals. Phase shift:
90º ± 10º
I0 signal. Amplitude:
0.2 ÷ 0.85 V
I0 signal. Width:
T-90º =< I0 =< T+180º
A
B
Io
V1
V2
VApp
VBpp
VIopp