Hardware configuration.
CNC 8070
CENTRAL U
N
IT
FOR C
ABI
NET (Q7-A
PLATFORM).
7.
Conn
ecti
ons.
·163·
(R
EF
: 1911)
Probe whose output has a normally closed contact. Connection to +24 V.
The connection acts upon the up flank (positive pulse) of the probe signal.
Interface with an open-collector output. Connection to +5 V.
The connection acts upon the down flank (negative pulse) of the probe signal.
Interface with an open-collector output. Connection to +24 V.
The connection acts upon the down flank (negative pulse) of the probe signal.
Interface with a PUSH-PULL output. Connection to +5 V.
Depending on the interface being used, the connection acts upon the up flank or down flank
of the probe signal.