Hardware configuration.
CNC 8070
CENTRAL
UNIT + MONITO
R (ETX PLATFORM).
5.
Enclo
sure and securi
ng of
mod
els C70
-1
0 / C70
-15.
·57·
(R
EF
: 1911)
5.5
Enclosure and securing of models C70-10 / C70-15.
5.5.1
Ambient characteristics of the enclosure.
The enclosure must ensure that the temperature inside does not exceed 55 C (131 ºF) while
the device is in operating mode, with an ambient temperature of 45 ºC (113 ºF).
5.5.2
Enclosure design.
The enclosure must meet the following requirements:
• The enclosure must have enough surface area to evacuate by convection the heat
generated inside.
• The enclosure must respect the minimum distances recommended between the
enclosure walls and the central unit to let the air flow and improve heat dissipation.
• In the connector area, reserve a space that allows the cables to be connected, respecting
their radius of curvature. Special care must be taken with the Sercos connection because
bending the optic fiber too much could break it
• Keep the enclosure clean.
To meet the previous requirements, Fagor recommends the following.
• The enclosure must have an air input next to the cables and an air output next to the fan.
In this case, install fans to ventilate the enclosure and keep the temperature within the
allowed limits. Bear in mind that this air flow through the unit extracts hot air to the outside,
but it allows dirt into the enclosure. Fagor recommends installing anti-dust filters at the
air inputs and outputs.
Dimensions of the cut off part and the enclosure.
C70-10K.
Before building an enclosure with glass fiber u another poor heat dissipating material, contact Fagor
Automation.
i
mm
inch
W
391
15.40
H
321
12.63
H
W
e
D
(*) Minimum recommended distance.
mm
inch
D (*)
174
6.85
e
1.5 ~ 4.0
0.06 ~ 0.16
Summary of Contents for CNC 8070
Page 1: ...Ref 1911 8070 CNC Hardware configuration...
Page 8: ...BLANK PAGE 8...
Page 14: ...BLANK PAGE 14...
Page 18: ...BLANK PAGE 18...
Page 22: ...BLANK PAGE 22...
Page 24: ...BLANK PAGE 24...
Page 26: ...BLANK PAGE 26...
Page 28: ...Hardware configuration CNC 8070 1 PREVIOUS INFORMATION 28 REF 1911...
Page 94: ...Hardware configuration CNC 8070 6 CENTRAL UNIT MONITOR Q7 A PLATFORM 94 REF 1911 C70 15AT...
Page 273: ...Hardware configuration CNC 8070 273 User notes REF 1911...
Page 274: ...Hardware configuration CNC 8070 274 User notes REF 1911...
Page 275: ...Hardware configuration CNC 8070 275 User notes REF 1911...