AUXILIARY SERVICES
WARNING
During the programming mode the activation
of an alarm input, the expiration of a timer
etc.. don’t initiate an action or a sequence of
actions.
Digital inputs
Europa GSM is provided with 4 digital inputs (All 1 ~ All 4) which can be
programmed as normally closed or normally open.
When ignition conditions occur (opening or closing the contact) Europa GSM
will perform the associated action sequence, or it will recall a profile. The
configuration of the digital inputs and of the actions following an alarm must be
made via the remote programmer software.
Note: recalling a profile by closing or opening an alarm input,
requires the “automatic mode” set during the “Recalling a
profile” programming.
DEFAULT
:
- All 1 input: upon closure of the contact sequence 1 is initiated;
- All 2 input: upon closure of the contact sequence 2 is initiated;
- All 3 input: not programmed;
- All 4 input: upon closure of the contact the ABSENT profile is recalled.
Timer
Europa GSM is provided with 8 programmable time events. When the set date
and time come, the action sequence is initiated.
Action sequences must be assigned to time events via remote programmer
software.
DEFAULT
: no set timer.
System events
Europa GSM is provided with 3 system events: absence of electric power
supply, restoration of electric power supply and discharged battery.
When these events occur, an action sequence is initiated.
Action sequences must be assigned to system events via remote programmer
software.