PROGRAMMINGS
Page
91
A
CTUATOR RELAY CONFIGURATION
Europa GSM has 5 actuator relays.
Note: in presence of a traditional doorphone board, relays 4 and 5
can also be activated through the door opening function, if
the impulse functioning is not enabled.
This programming allows configuring each actuator relay:
1
Local access
with password
Determines whether the extensions should enter a
password to use the relays.
2
Deactivation
Determines whether it is possible to deactivate the
relay (open contact).
3
Activation
Determines whether it is possible to activate the
relay (close contact).
4
Impulse
Determines whether it is possible to activate the
relay for a fixed programmed amount of time (the
closure time of the contact can be set only via
remote programmer software).
5
Time-set
Determines whether it is possible to activate the
relay for the amount of time specified when
requiring the service.
6 Relay condition
at startup
Determines the relay status at the startup of Europa
GSM: activated, deactivated or automatic (that is,
the relay will assume the status at the previous
switch-off).
DEFAULT
:
- local access with password: password required for all relays;
- deactivation: all relays are deactivated;
- activation: all relays can be activated;
- impulse: all relays can be activated for a pre-set amount of time;
- time-set: all relays can be activated for the amount of time specified when
requiring the service;
- relay condition at startup: all relays are deactivated.
Summary of Contents for Europa GSM
Page 1: ...USER S MANUAL Installation and use...
Page 154: ...EUROPA GSM 21 11 2012 edition...