Programmings to be performed during installation phase
The input and alarm sequence configurations can only be carried out through
the remote programmer software.
Telephone number programming
(index)
...
(telephone number)
(confirm)
¾
Pick up the handset of the system administrator extension (extension
41).
¾
Dial the code 2930.
¾
Dial:
097
to memorise the first telephone number
098
to memorise the second telephone number
099
to memorise the third telephone number
100
to memorise the fourth telephone number.
¾
Dial the telephone number to which send the alarm call.
¾
Dial # to confirm.
¾
Wait for the confirmation tone and hang up.
Note: as a factory setting, numbers stored in position 097 and 098
are also numbers to which notification SMSs regarding
electric power supply absence/restoration, and low battery
are sent.
P
ROGRAMMING OF THE SWITCHBOARD MODEL
AND OF THE INTERNAL CONNECTION TO THE
PERSONAL PHONE
These parametres must necessarily be programmed
for a correct operation of the ST 600 Personal
Phone.
The programming of the switchboard model allows setup of the switchboard
model to which the telephone is connected.
The programming of the internal connection allows the setup of the
switchboard port to which the telephone is connected.