4.2.7.8 CR Encoder Sensor
1.
2.
Move "Carriage Unit" to center of printer and remove the "Carriage Cover".
(Refer to "4.2.4.3 C593_SUB Board" (p234).)
3.
Disconnect the FFC from "CR Encoder Sensor".
4.
Remove the screw securing "CR Encoder Sensor" to the "Carriage Unit"
and remove "CR Encoder Sensor".
C.P.P. 2.6x6:
1 pc.
Figure 4-99. CR Encoder Sensor Removal
C A U T I O N
Do not touch "Scale, CR" when removing "CR Encoder
Sensor".
Align the two dowels on the "CR Encorder Sensor" with the
two positioning holes on the "Ink Tube Unit".
A D J U S T M E N T
R E Q U I R E D
Be sure to refer to Chapter 5
and
perform specified adjustments after replacing or installing
the "CR Encoder Sensor".
Dowels
Positioning holes
C.P.P. 2.6x6
Scale, CR
FFC
Shield Plate
CR Encoder Sensor