Maintenance 4. Cable
N6 Rev.2
189
The subsequent steps are described with the standard model’s cable unit.
For cleanroom model, a yellow air tube is included in the cable unit.
Installation
Cable Unit
(Cable direction:
Upward and
Downward)
(1) Perform the Installation steps (1) through (8) in
Maintenance 4.1 Cable Unit: Cable
direction Standard (backward)
.
(2) Lay down the Manipulator.
Manipulator is heavy. Be sure to have at least 2 people to perform the operation.
(3) Pull out the cable unit except the following
cables.
Cables (connectors):
BRK_CN2, EB01_CN3, ground wire
(4) Connect the connectors to the plate part 3
Connectors: X11, X12, X010, BR010
There are the front side and the back side on
the plate part 3. Be careful for the directions.
Front
Refer to the right picture for installation
direction of black colored connectors (X010,
BR010).
Back
A
B
A
B
For cleanroom model, connect the yellow air
tube to the fittings.
Back
NOTE
NOTE
NOTE
Summary of Contents for N6 Series
Page 1: ...Rev 2 EM187R3735F 6 Axis Robots N6 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual N6 series Rev 2 ...
Page 8: ...vi N6 Rev 2 ...
Page 14: ......
Page 27: ...Setup Operation 1 Safety N6 Rev 2 15 N6 A850 R C A D F G F E H G F B G F G F F F N6 A850 BR F ...
Page 34: ...Setup Operation 2 Specifications 22 N6 Rev 2 N6 A850 BR Cable direction Upward ...
Page 52: ...Setup Operation 3 Environment and Installation 40 N6 Rev 2 N6 A850 R Maximum motion range 802 ...
Page 66: ...Setup Operation 4 End Effectors 54 N6 Rev 2 N6 A850 R Unit mm ...
Page 104: ......
Page 274: ...Maintenance 4 Cable 262 N6 Rev 2 4 7 1 Signal Power cable ...
Page 275: ...Maintenance 4 Cable N6 Rev 2 263 ...
Page 276: ...Maintenance 4 Cable 264 N6 Rev 2 4 7 2 User Cable ...