Maintenance 5. Actuator Units
N6 Rev.2
309
Removal
(1) Turn ON the Controller.
Joint #6
Motor Unit
(2) Release the brake on the Joint #2 and Joint #3.
EPSON
RC+
Command
> brake off, 2
> brake off, 3
When releasing the brake, be careful of the arm falling due to its own weight.
(3)
Move the angles of the Arm #2 and the Arm #3 about 30 degrees from the origin
positions.
N6-A1000**
N6-A850**R
(4) Turn OFF the Controller.
(5) Remove the Arm #4 side cover (2 covers).
For details, refer to
Maintenance 3. Covers.
(6) Cut off the cable tie of the cables.
Be careful not to cut the cables.
(7) Disconnect the connectors.
Connectors: PW6, BR6, EB0x_CN2 (Joint #6 motor side)
(8) Remove the bolts fixing the Arm #4 and the
Joint #6 motor unit. Then, remove the timing
belt of the Joint #6 motor unit and the Joint #6.
Hexagon socket head cap bolts: 2-M4×15
(with plain washer for slotted hole
thickness: 1.5mm)
If a heavy part such as end effector is installed on the end of the Manipulator, the
Arm #6 flange will move. Be very careful.
NOTE
NOTE
NOTE
Summary of Contents for N6 Series
Page 1: ...Rev 2 EM187R3735F 6 Axis Robots N6 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual N6 series Rev 2 ...
Page 8: ...vi N6 Rev 2 ...
Page 14: ......
Page 27: ...Setup Operation 1 Safety N6 Rev 2 15 N6 A850 R C A D F G F E H G F B G F G F F F N6 A850 BR F ...
Page 34: ...Setup Operation 2 Specifications 22 N6 Rev 2 N6 A850 BR Cable direction Upward ...
Page 52: ...Setup Operation 3 Environment and Installation 40 N6 Rev 2 N6 A850 R Maximum motion range 802 ...
Page 66: ...Setup Operation 4 End Effectors 54 N6 Rev 2 N6 A850 R Unit mm ...
Page 104: ......
Page 274: ...Maintenance 4 Cable 262 N6 Rev 2 4 7 1 Signal Power cable ...
Page 275: ...Maintenance 4 Cable N6 Rev 2 263 ...
Page 276: ...Maintenance 4 Cable 264 N6 Rev 2 4 7 2 User Cable ...