Maintenance 4. Cable
244
N6 Rev.2
Removal
Joint #5
Motor Unit
Relay Cable 1
(1) Remove the Arm #4 side cover (2 covers).
For details, refer to
Maintenance 3.14 Arm #4 Side Cover.
(2) Cut off the cable tie that bundles the cables,
then disconnect the connector from the encoder
board #4.
Connector:
EB0x_CN2 (Joint #5 motor connection)
You do not need to disconnect the connector
connected to the Joint #6 motor.
Joint #5 motor
Joint #6 motor
(3) Remove the encoder cover.
Cross recessed head screws: 3-M2.5
×
6
Encoder
cover
(4) Disconnect the connector.
Connector: ENC_x
NOTE