Maintenance 5. Actuator Units
282
N6 Rev.2
5.2.1 Joint #2 (N6-A1000**)
Removal
Joint #2
Actuator Unit
N6-A1000**
(1) Remove the covers.
Arm #4 side cover (2 covers), Joint #4 inside cover, Joint #4 outside cover
Joint #4 side cover (2 covers), Arm #3 cover, Arm 3 inside cover,
Arm #2 cover (2 covers), Joint #2 cover, Joint #2 outside cover
For details, refer to
Maintenance 3. Covers.
(2) Remove the cable unit from Joint #1 to Joint #2.
For details, refer to the Removal steps (2) through (5), (9) through (37), and (42) in
Maintenance 4.1 Cable Unit (N6-A1000*) : Cable direction Standard (backward).
(3) Remove the Joint #2 actuator unit and the
O-ring.
Hexagon socket head cap bolts:
16-M5
×
35 (with plain washer)
Be sure to have at least 2 people to perform the
operation since the parts being heavy.
Do not apply excessive shock to the parts.
Joint #2 actuator unit
16-M5
×
35 (with plain washer)
NOTE
Summary of Contents for N6 Series
Page 1: ...Rev 2 EM187R3735F 6 Axis Robots N6 series MANIPULATOR MANUAL ...
Page 2: ...Manipulator manual N6 series Rev 2 ...
Page 8: ...vi N6 Rev 2 ...
Page 14: ......
Page 27: ...Setup Operation 1 Safety N6 Rev 2 15 N6 A850 R C A D F G F E H G F B G F G F F F N6 A850 BR F ...
Page 34: ...Setup Operation 2 Specifications 22 N6 Rev 2 N6 A850 BR Cable direction Upward ...
Page 52: ...Setup Operation 3 Environment and Installation 40 N6 Rev 2 N6 A850 R Maximum motion range 802 ...
Page 66: ...Setup Operation 4 End Effectors 54 N6 Rev 2 N6 A850 R Unit mm ...
Page 104: ......
Page 274: ...Maintenance 4 Cable 262 N6 Rev 2 4 7 1 Signal Power cable ...
Page 275: ...Maintenance 4 Cable N6 Rev 2 263 ...
Page 276: ...Maintenance 4 Cable 264 N6 Rev 2 4 7 2 User Cable ...