10 Technical data
Hauser
99
10.1.7
Operating conditions
Installation
Installation instructions
Any orientation (vertical, horizontal)
Restrictions and additional installation instructions
Inlet and outlet runs
Clamp-on version
Insertion version
Connecting cable length
Shielded cables are offered in the following lengths:
5 m, 10 m, 15 m and 30 m
Route the cable well clear of electrical machines and switching elements.
Environment
Ambient temperature
• Transmitter Prosonic Flow 90:
–20...+60 °C
optionally: –40...+60°C
!
Note!
At ambient temperatures below –20°C the readability of the display may be impaired.
• Flowrate measuring sensors Prosonic Flow P (clamp-on):
–40...+80 °C / 0...+170 °C
• Flowrate measuring sensors Prosonic Flow W (clamp-on):
–20...+80 °C
• Flowrate measuring sensors Prosonic Flow U (clamp-on):
–20...+60 °C
• Flowrate measuring sensors Prosonic Flow W (Insertion):
–40...+80 °C
• Sensor cable PTFE: –40...+170 °C; Sensor cable PVC: –20...+70 °C
• In heated piping or piping conveying cold fluids, it is always permissible to insulate the piping
completely with the mounted ultrasonic sensors.
• Install the transmitter at a shady location. Avoid direct sunlight, particularly in warm climatic
regions.
Storage temperature
The storage temperature corresponds to the operating temperature range of the measuring transmit-
ter and the appropriate measuring sensors and the corresponding sensor cable (see above).
Degree of protection
• Transmitter Prosonic Flow 90:
IP 67 (NEMA 4X)
• Flowrate measuring sensors Prosonic Flow P (clamp-on):
IP 68 (NEMA 6P)
• Flowrate measuring sensors Prosonic Flow W (clamp-on):
IP 67 (NEMA 4X)
• Flowrate measuring sensors Prosonic Flow U (clamp-on):
IP 54
• Flowrate measuring sensors Prosonic Flow W (Insertion):
IP 68 (NEMA 6P)
Summary of Contents for Prosonic Flow 90
Page 4: ...Brief operating instructions Proline Prosonic Flow 90 4 Endress Hauser...
Page 42: ...4 Wiring Proline Prosonic Flow 90 42 Endress Hauser...
Page 62: ...5 Operation Proline Prosonic Flow 90 62 Endress Hauser...
Page 74: ...7 Maintenance Proline Prosonic Flow 90 74 Endress Hauser...
Page 78: ...8 Accessories Proline Prosonic Flow 90 78 Endress Hauser...
Page 94: ...9 Trouble shooting Proline Prosonic Flow 90 94 Endress Hauser...
Page 108: ...10 Technical data Proline Prosonic Flow 90 108 Endress Hauser...
Page 112: ...Index Proline Prosonic Flow 90 112 Endress Hauser...
Page 114: ...www endress com worldwide BA068D 06 en 11 04 50099981 FM SGLM6 0...