1 Safety instructions
Hauser
7
1
Safety instructions
1.1
Designated use
The measuring device described in these Operating Instructions is to be used only for measuring the
flow of liquids in closed pipes, e.g.:
• Ultra clean water with low conductivity
• Water, wastewater, etc.
As well as measuring the volume flow, the measuring system also always measures the sound
velocity of the fluid. The sound velocity can be used to distinguish different fluids or as a measure
of fluid quality.
The manufacturer accepts no liability for damage resulting from incorrect use or other than
designated use.
1.2
Installation, commissioning and operation
Note the following points:
• Installation, connection to the electricity supply, commissioning and maintenance of the device
must be carried out by trained, qualified specialists authorized to perform such work by the facil-
ity's owner-operator. The specialist must have read and understood these Operating Instructions
and must follow the instructions they contain.
• The device must be operated by persons authorized and trained by the plant operator.
Strict compliance with the instructions in the Operating Instructions is mandatory.
• Hauser will be happy to assist in clarifying the chemical resistance properties of parts
wetted by special fluids, including fluids used for cleaning.
• If welding work is performed on the piping system, do not ground the welding appliance through
the Prosonic flowmeter.
• The installer must ensure that the measuring system is correctly wired in accordance with the
wiring diagrams. The transmitter must be grounded, unless the power supply is galvanically
isolated.
• Invariably, local regulations governing the opening and repair of electrical devices apply.
1.3
Operational safety
Note the following points:
• Measuring systems for use in hazardous environments are accompanied by separate “Ex docu-
mentation”, which is an
integral
part
of these Operating Instructions. Strict compliance with the
installation instructions and connection data as listed in the supplementary “Ex” documentation
is mandatory. The symbol on the front of the Ex documentation indicates the approval and the
certification body (
0
Europe,
2
USA,
1
Canada).
• The measuring device complies with the general safety requirements in accordance with
EN 61010, the EMC requirements of EN 61326/A1, and NAMUR Recommendation NE 21.
• The manufacturer reserves the right to modify technical data without prior notice. Your
Hauser distributor will supply you with current information and updates to these
Operating Instructions.
Summary of Contents for Prosonic Flow 90
Page 4: ...Brief operating instructions Proline Prosonic Flow 90 4 Endress Hauser...
Page 42: ...4 Wiring Proline Prosonic Flow 90 42 Endress Hauser...
Page 62: ...5 Operation Proline Prosonic Flow 90 62 Endress Hauser...
Page 74: ...7 Maintenance Proline Prosonic Flow 90 74 Endress Hauser...
Page 78: ...8 Accessories Proline Prosonic Flow 90 78 Endress Hauser...
Page 94: ...9 Trouble shooting Proline Prosonic Flow 90 94 Endress Hauser...
Page 108: ...10 Technical data Proline Prosonic Flow 90 108 Endress Hauser...
Page 112: ...Index Proline Prosonic Flow 90 112 Endress Hauser...
Page 114: ...www endress com worldwide BA068D 06 en 11 04 50099981 FM SGLM6 0...