10 Technical data
Proline Prosonic Flow 90
98
Hauser
10.1.6
Performance characteristics
Reference operating
conditions
• Fluid temperature: +28 °C ± 2 K
• Ambient temperature: +22 °C ± 2 K
• Warm-up period: 30 minutes
Installation:
• Inlet run >10 x DN
• Outlet run > 5 x DN
• Sensor and transmitter grounded.
Maximum measured error
For flow velocities of > 0.3 m/s and a Reynolds number of >10000, the system accuracy is:
• Pipe diameter DN < 50: ± 0.5 % o.r. ± 0.1 % o.f.s. *
• Pipe diameter 50 < DN < 200: ± 0.5 % o.r. ± 0.05 % o.f.s.
• Pipe diameter DN > 200: ± 0.5 % o.r. ± 0.02 % o.f.s.
o.r. = of reading
o.f.s. = of full scale value
* plastic pipes only
As standard, the system is dry-calibrated. The dry calibration procedure results in an additional
uncertainty of measurement. This measuring uncertainty is better than 1.5% typically. During dry
calibration, the characteristics of the pipe and the fluid are derived to calculate the calibration factor.
As verification of the accuracy, an accuracy report is offered as an option.
Accuracy is verified using a stainless steel pipe.
A0001149
Fig. 53:
Max. measured error (wet calibration) in % of reading
a = pipe diameter DN > 200
b = pipe diameter 50 < DN < 200
c = pipe diameter DN < 50
Repeatability
max. ± 0.3% for flow velocities > 0.3 m/s
0
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
%
m/s
a
b
c
2
4
6
8
10
12
14
Summary of Contents for Prosonic Flow 90
Page 4: ...Brief operating instructions Proline Prosonic Flow 90 4 Endress Hauser...
Page 42: ...4 Wiring Proline Prosonic Flow 90 42 Endress Hauser...
Page 62: ...5 Operation Proline Prosonic Flow 90 62 Endress Hauser...
Page 74: ...7 Maintenance Proline Prosonic Flow 90 74 Endress Hauser...
Page 78: ...8 Accessories Proline Prosonic Flow 90 78 Endress Hauser...
Page 94: ...9 Trouble shooting Proline Prosonic Flow 90 94 Endress Hauser...
Page 108: ...10 Technical data Proline Prosonic Flow 90 108 Endress Hauser...
Page 112: ...Index Proline Prosonic Flow 90 112 Endress Hauser...
Page 114: ...www endress com worldwide BA068D 06 en 11 04 50099981 FM SGLM6 0...