Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide
211
Issue Number: 5 www.controltechniques.com
Table 11-7 Applications module parameters
Parameter
Range(
Ú
)
Default(
Ö
)
Type
x.01
Solutions Module ID
0 to 599
RO Uni
PT US
x.02
Solutions Module software version
0.00 to 99.99
RO Uni
NC PT
x.03
DPL program status
None (0), Stop (1), Run (2), Trip (3)
RO Txt
NC PT
x.04
Available system resource
0 to 100
RO Uni
NC PT
x.05
RS485 address
0 to 255
11
RW Uni
US
x.06
RS485 mode
0 to 255
1
RW Uni
US
x.07
RS485 baud rate
300 (0), 600 (1), 1200 (2), 2400 (3), 4800 (4),
9600 (5), 19200 (6), 38400 (7), 57600 (8),
115200 (9) baud
4800 (4)
RW Txt
US
x.08
RS485 Turnaround delay
0 to 255 ms
2
RW Uni
US
x.09
RS485 Tx enable delay
0 to 1 ms
0
RW Uni
US
x.10
DPL Print Routing
SYPT: OFF (0), RS485: On (1)
SYPT: OFF (0)
RW Bit
US
x.11
Clock task scheduling (ms)
0 to 200
10
RW Uni
US
x.12
POS task scheduling rate
dISAbLEd (0), 0.25 ms (1), 0.5 ms (2), 1 ms (3),
2 ms (4), 4 ms (5), 8 ms (6)
dISAbLEd (0)
RW Txt
US
x.13
Enable autorun
OFF (0) or On (1)
On (1)
RW Bit
US
x.14
Global run time trip enable
OFF (0)
RW Bit
US
x.15
Disable reset on trip cleared
RW Bit
US
x.16
Encoder data update rate
0 to 3
0
RW Uni
US
x.17
Enable parameter over range trips
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.18
Watchdog enable
RW Bit
US
x.19
Save request
RW Bit
NC
x.20
Enable power down save
RW Bit
US
x.21
Enable menu 20 save and
restore
RW Bit
US
x.22
CTNet Token Ring ID
0 to 255
0
RW Uni
US
x.23
CTNet node address
0
RW Uni
US
x.24
CTNet baud rate
5.000 (0), 2.500 (1), 1.250 (2), 0.625 (3)
2.500 (1)
RW Txt
US
x.25
CTNet sync setup
0,000 to 9,999
0,000
RW Uni
US
x.26
CTNet easy mode - first cyclic
parameter destination node
0 to 25,503
0
RW Uni
US
x.27
CTNet easy mode - first cyclic source
parameter
0 to 9,999
RW Uni
US
x.28
CTNet easy mode - second cyclic
parameter destination node
0 to 25,503
RW Uni
US
x.29
CTNet easy mode - second cyclic
source parameter
0 to 9,999
RW Uni
US
x.30
CTNet easy mode - third cyclic
parameter destination node
0 to 25,503
RW Uni
US
x.31
CTNet easy mode - third cyclic source
parameter
0 to 9,999
RW Uni
US
x.32
CTNet easy mode set-up - Transfer
slot 1 destination parameter
0 to 9,999
RW Uni
US
x.33
CTNet easy mode set-up - Transfer
slot 2 destination parameter
0 to 9,999
RW Uni
US
x.34
CTNet easy mode set-up - Transfer
slot 3 destination parameter
0 to 9,999
RW Uni
US
x.35
CTNet sync event task ID
Disabled (0), Event (1), Event1 (2), Event2 (3),
Event3 (4)
Disabled (0)
RW Txt
US
x.36
CTNet diagnostic parameter
-3 to +32,767
RO Uni
NC PT
x.37
Reject download if drive enabled
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.38
APC run-time trip
RW Bit
US
x.39
Inter-module synchronization status
0 to 3
0
RO Uni
NC
x.41
Indexer control
0 to 255
RW Uni
NC
x.42
Pass freeze through drive
OFF (0) or On (1)
OFF (0)
RW Bit
US
x.43
Freeze invert
RW Bit
US
x.44
Task priority level
0 to 255
0
RW Uni
US
x.45
User set-up parameter 1
0 to 65535
RO Uni
NC
x.46
User set-up parameter 2
-32,768 to +32,767
RO Uni
NC
x.47
User set-up parameter 3
0 to 255
RO Uni
NC
x.48
DPL line number in error
0 to 2,147,483,647
0
RO Uni
NC PT
x.49
User program ID
-32,768 to +32,767
RO Bi
NC PT
x.50
Solutions Module error status*
0 to 255
RO Uni
NC PT
x.51
Solutions Module software sub-version
0 to 99
RO Uni
NC PT
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save
Summary of Contents for Affinity