Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide
207
Issue Number: 5 www.controltechniques.com
Figure 11-38 SM-I/O 24V Protected analog output logic diagram
SM-I/O 24V Protected parameters
0.XX
0.XX
Key
Read-write (RW)
parameter
Read-only (RO)
parameter
Input
terminals
Output
terminals
The parameters are all shown at their default settings
T12 Analog output 2
T10 Analog output 1
10
Parameter
Range(
Ú
)
Default(
Ö
)
Type
x.01
Solutions Module ID
0 to 599
205
RO
Uni
PT
US
x.02
Solutions Module Main Software Version
0.00 to 99.99
RO
Uni
NC
PT
x.03
T5 digital I/O 3 state
OFF (0) or On (1)
RO
Bit
NC
PT
x.04
T6 digital I/O 4 state
RO
Bit
NC
PT
x.05
T7 digital input 5 state
RO
Bit
NC
PT
x.06
T8 digital input 6 state
RO
Bit
NC
PT
x.07
T9 digital input 7 state
RO
Bit
NC
PT
x.08
Relay 1 state
RO
Bit
NC
PT
x.09
T3 digital I/O 1 state
RO
Bit
NC
PT
x.10
T4 digital I/O 2 state
RO
Bit
NC
PT
x.11
T3 digital I/O 1 invert
OFF (0)
RW
Bit
US
x.12
T4 digital I/O 2 invert
RW
Bit
US
x.13
T5 digital I/O 3 invert
RW
Bit
US
x.14
T6 digital I/O 4 invert
RW
Bit
US
x.15
T7 digital input 5 invert
RW
Bit
US
x.16
T8 digital input 6 invert
RW
Bit
US
x.17
T9 digital input 7 invert
RW
Bit
US
x.18
Relay 1 invert
RW
Bit
US
x.20
Digital I/O read word
0 to 255
RO
Uni
NC
PT
x.21
T3 digital I/O 1 source/destination
Pr
0.00
to
Pr
50.99
Pr
0.00
RW
Uni
DE
US
x.22
T4 digital I/O 2 source/destination
RW
Uni
DE
US
x.23
T5 digital I/O 3 source/destination
RW
Uni
DE
US
x.24
T6 digital I/O 4 source/destination
RW
Uni
DE
US
x.25
T7 digital input 5 destination
RW
Uni
DE
US
x.26
T8 digital input 6 destination
RW
Uni
DE
US
x.27
T9 digital input 7 destination
RW
Uni
DE
US
x.28
Relay 1 source
RW
Uni
US
x.29
T6 digital I/O 4 output select
OFF (0) or On (1)
On (1)
RW
Bit
US
x.31
T3 digital I/O 1 output select
OFF (0)
RW
Bit
US
x.32
T4 digital I/O 2 output select
RW
Bit
US
x.33
T5 digital I/O 3 output select
RW
Bit
US
x.39
Analog output mode
0-20, 20-0, 4-20, 20-4
0-20
RW
Uni
US
x.40
Relay 2 state
0.0 or 100.0 %
RO
Bit
NC
PT
x.42
Relay 2 invert
OFF (0) or On (1)
OFF (0)
RW
Bit
US
x.43
Relay 2 source
Pr
0.00
to
Pr
50.99
Pr
0.00
RW
Uni
US
x.45
Analog output 2 scaling
0.000 to 4.000
1.000
RW
Uni
US
x.47
Analog output 2 source
Pr
0.00
to
Pr
50.99
Pr
0.00
RW
Uni
US
x.48
Analog output 1 source
RW
Uni
US
x.49
Analog output 1 scaling
0.000 to 4.000
1.000
RW
Uni
US
x.50
Solutions Module error status
0 to 255
RO
Uni
NC
PT
x.51
Solutions Module software sub-version
0 to 99
RO
Uni
NC