Safety
Information
Product
Information
Mechanical
Installation
Electrical
Installation
Getting
Started
Basic
parameters
Running
the motor
Optimization
SMARTCARD
operation
PC tools
Advanced
parameters
Technical
Data
Diagnostics
UL Listing
Information
Affinity User Guide
175
Issue Number: 5 www.controltechniques.com
11.10 Menu 10: Status and trips
Parameter
Range(
Ú
)
Default(
Ö
)
Type
OL
RFC
OL
RFC
10.01
Drive OK
OFF (0) or On (1)
RO
Bit
NC PT
10.02
Drive active
RO
Bit
NC PT
10.03
Zero speed
RO
Bit
NC PT
10.04
Running at or below minimum speed
RO
Bit
NC PT
10.05
Below set speed
RO
Bit
NC PT
10.06
At speed
RO
Bit
NC PT
10.07
Above set speed
RO
Bit
NC PT
10.08
Load reached
RO
Bit
NC PT
10.09
Drive output is at current limit
RO
Bit
NC PT
10.10
Regenerating
RO
Bit
NC PT
10.11
Braking IGBT active
RO
Bit
NC PT
10.12
Braking resistor alarm
RO
Bit
NC PT
10.13
Direction commanded
OFF (0) or On (1) [0 = FWD, 1 = REV]
RO
Bit
NC PT
10.14
Direction running
RO
Bit
NC PT
10.15
Line power supply loss
OFF (0) or On (1)
RO
Bit
NC PT
10.16
Under voltage active
RO
Bit
NC PT
10.17
Overload alarm
RO
Bit
NC PT
10.18
Drive over temperature alarm
RO
Bit
NC PT
10.19
Drive warning
RO
Bit
NC PT
10.20
Trip 0
0 to 232*
RO Txt
NC PT PS
10.21
Trip 1
RO Txt
NC PT PS
10.22
Trip 2
RO Txt
NC PT PS
10.23
Trip 3
RO Txt
NC PT PS
10.24
Trip 4
RO Txt
NC PT PS
10.25
Trip 5
RO Txt
NC PT PS
10.26
Trip 6
RO Txt
NC PT PS
10.27
Trip 7
RO Txt
NC PT PS
10.28
Trip 8
RO Txt
NC PT PS
10.29
Trip 9
RO Txt
NC PT PS
10.30
Full power braking time
0.00 to 400.00 s
See Table 11-6
RW Uni
US
10.31
Full power braking period
0.0 to 1500.0 s
See Table 11-6
RW Uni
US
10.32
External trip
OFF (0) or On (1)
OFF (0)
RW Bit
NC
10.33
Drive reset
RW Bit
NC
10.34
No. of auto-reset attempts
0 to 6 (inf)
0
RW Txt
US
10.35
Auto-reset delay
0.0 to 25.0 s
1.0
RW Uni
US
10.36
Hold drive OK until last attempt
OFF (0) or On (1)
OFF (0)
RW Bit
US
10.37
Action on trip detection
0 to 15
0
RW Uni
US
10.38
User trip
0 to 255
RW Uni
NC
10.39
Braking energy overload accumulator
0.0 to 100.0 %
RO Uni
NC PT
10.40
Status word
0 to 32,767
RO Uni
NC PT
10.41
Trip 0 date
0.00 to 31.12
RO Uni
NC PT PS
10.42
Module number for trip 0, or, Trip 0 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.43
Trip 1 date
0.00 to 31.12
RO Uni
NC PT PS
10.44
Module number for trip 1, or, Trip 1 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.45
Trip 2 date
0.00 to 31.12
RO Uni
NC PT PS
10.46
Module number for trip 2, or, Trip 2 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.47
Trip 3 date
0.00 to 31.12
RO Uni
NC PT PS
10.48
Module number for trip 3, or, Trip 3 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.49
Trip 4 date
0.00 to 31.12
RO Uni
NC PT PS
10.50
Module number for trip 4, or, Trip 4 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.51
Trip 5 date
0.00 to 31.12
RO Uni
NC PT PS
10.52
Module number for trip 5, or, Trip 5 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.53
Trip 6 date
0.00 to 31.12
RO Uni
NC PT PS
10.54
Module number for trip 6, or, Trip 6 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.55
Trip 7 date
0.00 to 31.12
RO Uni
NC PT PS
10.56
Module number for trip 7, or, Trip 7 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.57
Trip 8 date
0.00 to 31.12
RO Uni
NC PT PS
10.58
Module number for trip 8, or, Trip 8 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.59
Trip 9 date
0.00 to 31.12
RO Uni
NC PT PS
10.60
Module number for trip 9, or, Trip 9 time
00.00 to 23.59 hours.minutes
RO Uni
NC PT PS
10.61
Low load detected alarm
OFF (0) or On (1)
RO
Bit
PT
RW Read / Write
RO
Read only
Uni
Unipolar
Bi
Bi-polar
Bit
Bit parameter
Txt
Text string
FI
Filtered
DE
Destination
NC
Not copied
RA
Rating dependent
PT
Protected
US
User save
PS
Power down save
Summary of Contents for Affinity
Page 274: ...0474 0000 05 ...