38
SMG digital gateway
E1 stream # failure
E1 stream failure
SS-7 link failure Link set #, E1 stream #
SS-7 link failure
Synchronisation with a local source. All specified
sources are inoperable
Synchronisation source is lost
E1 stream # remote fault
E1 stream remote fault
Synchronisation from a lower priority source
Primary synchronisation source is lost, the priority of the
current source is lower
Failed to send CDR files via FTP
Failure to send a CDR file to FTP server
Running out of operating memory
One of RAM utilisation limits has been reached
High CPU temperature
One of CPU temperature limits has been reached
High CPU utilisation
One of CPU utilisation limits has been reached
Transit over E1 stream
setting up of semi-permanent connection over E1 channel
failed
The
Alarm events list
menu contains a list of alarm events arranged by time and date.
Alarm Table
Clear
—delete the existing fault events table.
№—fault sequential number.
Time
—fault occurrence time (HH:MM:SS).
Date
—fault occurrence date (DD/MM/YY).
Type
—a fault type:
–
CONFIG
—a critical fault, a configuration file fault;
–
SIPT-MODULE
—a critical fault, a failure of a program module responsible for VoIP
operation;
–
LINKSET
—a critical fault, an SS-7 line group is not in operation;
–
STREAM
—a critical fault, an E1 stream is not in operation;
–
SM-VP DEVICE
—a fault, a SM-VP module failure;
–
SS7 LINK
—an SS-7 signal channel failure;
–
SYNC
—a synchronisation fault, a synchronisation source is missing;
–
STREAM-REMOTE
—a warning, a remote fault of an E1 stream;
–
CDR-FTP
—a fault or a warning, a failure to send a CDR file to the FTP server.
–
TRANSIT –
critical alarm, setting up of semi-permanent connection over E1 channel failed.
State
—a fault state status:
critical alarm, LED blinking red
—the fault requires immediate intervention of the service
personnel and affects device operation and provisioning of communication services;
alarm, red LED
—non-critical fault, intervention of the service personnel is also required;