SMG digital gateway
179
calling-rule: ...xxxxxxx
calling-type: <no-change>
calling-numplan: no change
calling-present: no change
calling-screen: no change
calling-catAON: no change
SMG4-[CONFIG]-MODTABLE[2]>
change calling type 8 subscriber
// Change the type of the caller number to "subscriber"
Modifier. change_clg_type
'MODIFIER' [08]:
table: 2
mask: (383xxxxxxx)
numtype: any
AONcat: any
general-access: no change
general-numplan: no change
called-rule: $
called-type: <no-change>
called-numplan: no change
calling-rule: ...xxxxxxx
calling-type: <subscriber>
calling-numplan: no change
calling-present: no change
calling-screen: no change
calling-catAON: no change
SMG4-[CONFIG]-MODTABLE[2]>
exit
// Exit the modifier table configuration mode
Back to configuration mode.
SMG4-[CONFIG]>
trunk group
0
// Enter the trunk group configuration mode
Entering trunk-mode
SMG4-[CONFIG]-TRUNK[0]>
modifiers table
incoming calling
2
// Add the created modification table for modification of the
CgPN number in incoming communications
Trunk[0]. Set iModCld '7'
'TRUNK GROUP' [00]:
name: TrunkGroup00
disable out: no
disable in: no
reserv trunk: none
direct_pfx: none
RADIUS-profile: none
destination: Linkset [0]
local: no
Modifiers:
incoming calling: 2
incoming called: none
outgoing calling: none
outgoing called: none
outgoing redir: none
outgoing orig-cld: none
outgoing generic num:none
use in-band message: no
connected-num transit: normal