SMG digital gateway
143
<CALLING_SCREEN>
not_screened/
user_passed/
user_failed/
network/nochange
indicator modification rule
change calling type
<MODIFIER_INDEX>
<CALLING_TYPE>
0-8191
unknown/
subscriber/
national/
international/
network_specific/
nochange
Edit a caller number type
for the modifier:
MODIFIER_INDEX
—
modifier number;
CALLING_TYPE
—subscriber
number type:
-
Subscriber
—used for local
calls and incoming long-
distance calls;
-
National
—used
in
outgoing
long-distance
calls or in local calls and
incoming
long-distance
calls
instead
of
the
"
Subscriber
";
-
International
—used in LD
and CLR lines for outgoing
international calls;
-
network_specific
—a
specific network number;
-
unknown
—an unknown
number type;
-
nochange
—keep
the
number type unchanged.
change general access-
cat
<MODIFIER_INDEX>
<ACCESS>
0-8191
0-31/nochange
Edit the modifier's general
access category
change
general
numplan
<MODIFIER_INDEX>
<NUMPLAN>
0-8191
0-15/nochange
Edit the modifier's general
numbering schedule
change mask
<MODIFIER_INDEX>
<MODIFIER_MASK>
0-8191
a
modifier
mask,
255 characters max., should
be enclosed in parentheses "("
and ")"
Edit a modifier mask
MODIFIER_INDEX
—
modifier number;
MODIFIER_MASK
—mask.
change modtable
<MODIFIER_INDEX>
<NEW_MODTBL_INDEX
>
0-8191
0-255
Move the modifier into the
table with the specified
number
change numtype
<MODIFIER_INDEX>
<NUM_TYPE>
0-8191
unknown/
subscriber/
national/
international/
network_specific/
any
Edit the modifier's number
type:
MODIFIER_INDEX
—
modifier number;
NUM_TYPE
—subscriber
number type: