168
SMG digital gateway
timer (x100 ms)
set isup T24
<TIMER>
1-20
Set a value of ISUP T24 level
timer (x100 ms)
set isup T25
<TIMER>
10-100
Set a value of ISUP T25 level
timer (x100 ms)
set isup T26
<TIMER>
600-1800
Set a value of ISUP T26 level
timer (x100 ms)
set isup T33
<TIMER>
120-150
Set a value of ISUP T33 level
timer (x100 ms)
set isup T34
<TIMER>
20-40
Set a value of ISUP T34 level
timer (x100 ms)
set isup T35
<TIMER>
150-200
Set a value of ISUP T35 level
timer (x100 ms)
show
Show configuration
4.3.22
Sync Configuration Mode
To enter this mode, execute the
sync
command in the configuration mode.
SMG4-[CONFIG]> sync
Entering sync mode.
SMG4-[CONFIG]-SYNC>
Command
Parameter
Value
Action
?
Show the list of available commands
config
Return to the
Configuration
menu
exit
Return
from
this
configuration
submenu to an upper level
history
Show
the
history
of
entered
commands
new stream
<E1>
0-3
Set a synchronisation source from an
E1 stream
E1
—Е1 stream number.
quit
Terminate this CLI session
remove
<SOURCE>
0-3
Remove a synchronisation source
(specify the source number, but not
the number of the E1 stream)
show
Show information on synchronisation
sources configuration
timeout down
<TIMEOUT>
0-255
A time interval when the system does
not switch to a lower priority
synchronisation source in case of a
signal loss. If the signal is restored
during this interval, the system will not
switch to a lower priority source.
timeout up
<TIMEOUT>
0-255
A time interval when the restored
higher priority synchronisation signal
should be active for the system to
switch to that signal
4.3.23
Syslog Configuration Mode
To enter this mode, execute the syslog command in the configuration mode.
SMG4-[CONFIG]> syslog