166
SMG digital gateway
vbd enable
Enable V.152
vbd disable
Disable V.152
vbd payload type
<VBD_p>
Static,96-127
The payload type which is used for
the VBD codec
4.3.20
SS-7 Category Modification Configuration Mode
To enter this mode, execute the
ss7cat
command in the configuration mode.
SMG4-[CONFIG]> ss7cat
Entering SS7-categories mode.
SMG4-[CONFIG]-SS7-CAT>
Command
Parameter
Value
Action
?
Show the list of available commands
config
Return to the
Configuration
menu
exit
Return
from
this
configuration
submenu to an upper level
quit
Terminate this CLI session
set
<CAT_IDX>
<PBX_CAT>
<SS7_CAT>
0-15
0-255
0-255
Set a data category:
CAT_IDX
—category index;
PBX_CAT
—Caller ID category;
SS7_CAT
—SS-7 category.
show
Show information on SS-7 data
category
4.3.21
SS-7 Timer Configuration Mode
To enter this mode, execute the
ss7timers <SS7_TIMERS_INDEX>
command in the configuration mode,
where
<SS7_TIMERS_INDEX>
is a profile number.
SMG4-[CONFIG]> ss7timers 0
Entering SS7Timers-mode.
SMG4-[CONFIG]-SS7-TIMERS[0]>
Command
Parameter
Value
Action
?
Show the list of available
commands
config
Return to the
Configuration
menu
exit
Return from this configuration
submenu to an upper level
history
Show the history of entered
commands
quit
Terminate this CLI session
set mtp2 T1
<TIMER>
400-500
Set a value of MTP2 T1 level
timer (x100 ms)
set mtp2 T2
<TIMER>
50-500
Set a value of MTP2 T2 level
timer (x100 ms)
set mtp2 T3
<TIMER>
10-20
Set a value of MTP2 T3 level
timer (x100 ms)
set
mtp2
T4 <TIMER>
75-95
Set a value of MTP2 T4 normal