6
GW-GNET+
Page 104
gas-lab
Q1
These programs may only be activated if a data connection is established via
the DSS data interface.
Proceed as usual:
1. Start GW-BASE on your laptop computer.
2. Connect the DSS interface of the gas-net device to a COM interface of the
laptop using a parameterisation cable. Alternatively, you can use a USB-to-
serial converter cable to connect the parameterisation cable
3. Start the communication program by clicking the
Import
– Data interface
tool in the GW-BASE toolbar. After the data connection to the device has
been established, the type plate of the connected device appears on the
display.
4. Select the
Tools
tab. The appearing tab lists all available service programs.
5. Start the desired program by double-clicking.
The function range of the service programs is manageable and practical. The
operation is thus rather easy. A comprehensive online help is also available for
each program. It can be activated via the
Help
– Content
menu item or by
pressing the
F1
key.